Search results for "energy [jet]"
showing 10 items of 1760 documents
Generalized power-angle control for grid-forming converters: A structural analysis
2022
Several control schemes have been recently proposed and studied as grid-forming controls for power converters. In all these schemes, the power-angle control loop is the part which defines the fundamental capabilities of the grid-forming control: that control loop governs in fact the inherent synchronization mechanism of the power converter, the power sharing with the other generation sources in the system and the oscillatory characteristics of the converter-based resource. This article introduces a general formulation for the power-angle control characterizing the grid-forming concept for power converters. The generalized power-angle control is based on a polynomial fraction formulation, an…
Dendron to central core S1-S1 and S2-S(n) (n1) energy transfers in artificial special pairs containing dendrimers with limited numbers of conformatio…
2013
Two dendrimers consisting of a cofacial free-base bisporphyrin held by a biphenylene spacer and function- alized with 4-benzeneoxomethane (5-(4-benzene)tri-10,15,20-(4-n-octyl- benzene)zinc(II)porphyrin) using either five or six of the six available meso-positions, have been synthesized and characterized as models for the an- tenna effect in Photosystems I and II. The presence of the short linkers, -CH2O-, and long C8H17 soluble side chains substantially reduces the number of conformers (foldamers) compared with classic dendrimers built with longer flexible chains. This simpli- fication assists in their spectroscopic and photophysical analysis, notably with respect to fluorescence resonance…
Intramolecular electronic excitation energy transfer in donor∕acceptor dyads studied by time and frequency resolved single molecule spectroscopy
2008
Electronic excitation energy transfer has been studied by single molecule spectroscopy in donor/acceptor dyads composed of a perylenediimide donor and a terrylenediimide acceptor linked by oligo(phenylene) bridges of two different lengths. For the shorter bridge (three phenylene units) energy is transferred almost quantitatively from the donor to the acceptor, while for the longer bridge (seven phenylene units) energy transfer is less efficient as indicated by the occurrence of donor and acceptor emission. To determine energy transfer rates and efficiencies at the single molecule level, several methods have been employed. These comprise time-correlated single photon counting techniques at r…
Addressing Dendritic Cells for Anticancer Immunity
2014
Photocatalytic degradation of dyes by using a membrane reactor
2004
Abstract Dyes are organic compounds used in textile, food and drug industries, and their abatement represents one of the main problems in the treatment processes because generally they are very stable toxic compounds. In this work, two commercial azo-dyes, i.e. Congo Red (C32H22N6Na2O6S2) and Patent Blue (C27H31N2NaO6S2), in aqueous solution were degraded in a photocatalytic membrane reactor by using TiO2 Degussa P25 as the catalyst. Different system configurations and irradiating sources were studied, and the influence of some operational parameters such as the pressure in the membrane cell and the initial concentration of the substrates was determined. A comparison between suspended and e…
Photocatalytic formation of H2 and value-added chemicals in aqueous glucose (Pt)-TiO2 suspension
2016
Abstract Commercial and home prepared bare and Pt-supported TiO2 samples were used as the photocatalysts for the aqueous photo-conversion of glucose at ambient pressure and temperature. Aerobic and anaerobic conditions were used to study the products of glucose degradation both in the liquid (arabinose, erythrose, gluconic acid, glucaric acid, fructose and formic acid) and gaseous (H2 and CO2) phases. The distribution of these molecules was different in the presence of the various powders, depending on the structural and physico-chemical properties of the materials, and Pt resulted essential for the anaerobic production of H2. The home prepared samples resulted more active than the commerci…
Artificial neural network decision support tool for assessment of the energy performance and the refurbishment actions for the non-residential buildi…
2017
The public buildings sector represents one of the most intensive items of EU energy consumption; the application of retrofit solutions in existing buildings is a crucial way to reduce its impact. To facilitate the knowledge of the energy performance of existing non-residential buildings and the choice of the more adequate actions, Public Administrations (PA) should have the availability of proper tools. Within the Italian project "POI 2007-13", a database and a decision support tool, for easy use, even to a non-technical user, have been developed. A large set of data, obtained from the energy audits of 151 existing public buildings located in four regions of South Italy have been analysed, …
Energy management of multi-carrier smart buildings for integrating local renewable energy systems
2016
The proposed paper aims at defining a Building Management System (BMS) able to control energy flows inside a smart building integrated with various energy networks and Renewable Energy Resources (RES). The smart building envisaged in this work interacts with different energy carriers and is equipped with cogeneration and RES systems, as well as storage devices, which enable a certain degree of flexibility in the energy usage. The smart building is modelled as a multi-carrier hub, by defining the graphical and mathematical model of the building system. Moreover, the control criteria of the BMS are explained and the implementation of the BMS itself is depicted, along with some early results. …
A laboratory setup for the evaluation of the effects of BACS and TBM systems on lighting
2015
The paper focuses on the evaluation of the impact of Building Automation Control Systems (BACS) and Technical Building Management (TBM) systems on the performance of the lighting system in a residential building. In particular, this work shows a laboratory setup, installed at the DEIM of the University of Palermo, for simulating a typical apartment. The paper describes the laboratory, the lighting system and the BAC system installed and the test facility for evaluating the electricity consumption in presence and in absence of automation. The laboratory has been built within a research project funded by the Italian Minister of University and Research in the framework of the PON Smart Cities …
Improvement of Energy Efficiency for Indoor Lighting in a Big Shopping Center
2018
As the progressive diffusion of shopping centers in Italy, the paper analysis the potential energy savings in the indoor lighting plant, thanks to new technologies as LED lamps and Building Automation System. The case study, applied to a big shopping mall in the middle of Italy, shows great results, thanks to the high efficiency of LED technology, high number of operating hours and the implementation of a control system. An economic and environmental evaluation is reported.